The modular compact data center for the protection of your IT infrastructure.
Our DC-ITSafe edge micro datacenter also called MDC is available in different versions. These versions differ on variable positioned recesses for all important connections. This enables us to react purposeful on your individual requirements. Cable ducts can be placed in side panels as well as in floor and ceiling panels. Furthermore, if required it is possible to interconnect any number of Micro Data Center together and to link with each other. The DC-ITSafe can be scaled up easily as the IT needs grow, thus guaranteeing greatest possible flexibility.
The DC-ITSafe withstands the circumstances
and variety of various locations and is qualified across all businesses like
for example in small and mid-sized companies, companies with decentralized structures (Logistics and industrial
companies with various locations, chains), medical facilities like large group practices or hospitals, financial auditors, legal firms, engineering offices, architects or marketing
agencies. More and more of our customers select the DC-ITSafe as their edge micro datacenter solution and deploy it in every of their business location worldwide as part of their own compliance policy.
Benefit from space-saving all round protection for your IT infrastructure. You can determine the location for Mini Data Centers regardless of the spatial conditions in your company. Dusty production facilities with a high noise level or a heating room with high humidity? No problem for our DC-ITSafe! Our Edge Micro Center adapts to your requirements and protects your data also under difficult circumstances.
Technical features | DC-ITSafe HU 56 |
---|---|
OUTER DIMENSIONS | |
Width (mm) | 1,452 |
Height (mm) | 2,185 |
Depth (mm) | 1,470 |
Profile Frame (inch, mm) | 19": 800 x 1,200 |
HEIGHT UNITS | |
Horizontal | 44 |
Vertical | 12 |
Total | 56 |
WEIGHT | |
Weight empty (kg) | ca. 1,100 |
Maximum capacity 19” (kg) | 1,000 |
SETTING | |
Patented "click" assembly method | ● |
Self-locking, multiple automatic locking by massive swing fasteners and tightness elements | ● |
Number of soft ducts (optional hard ducts or firestop sleeve) | 4 |
Possible positioning cable dutcs | in the side, floor or ceiling elements |
Locking possibilities | Codecard lock, key lock and/or pin-code-terminal |
Technical features | DC-ITSafe HU 62 |
---|---|
OUTER DIMENSIONS | |
Width (mm) | 1,452 |
Height (mm) | 2,425 |
Depth (mm) | 1,470 |
Profile Frame (inch, mm) | 800 x 1,200 |
HEIGHT UNITS | |
Horizontal | 50 |
Vertical | 12 |
Total | 62 |
WEIGHT | |
Weight empty (kg) | ca. 1,100 |
Maximum capacity 19” (kg) | 1,000 |
SETTING | |
Patented "click" assembly method | ● |
Self-locking, multiple automatic locking by massive swing fasteners and tightness elements | ● |
Number of soft ducts (optional hard ducts or firestop sleeve) | 4 |
Possible positioning cable dutcs | in the side, floor or ceiling elements |
Locking possibilities | Codecard lock, key lock and/or pin-code-terminal |
Capacities:
1,6 kW - 4,5 kW
2,7 kW - 6,7 kW
3,3 kW - 8,1 kW
The DC-MonIToring system allows a direct online access to check the actual status of physical infrastructure components. Also available as MonIToring Alarm as option.
Appropriate precautions for your data safety (as option).
Early fire warning and extinguishing system for just 2 HU.
3-stage security concept:
1. Early, highly sensitive smoke detection
2. Automatic system shut-down
3. Extinguishing
Modular expandable by slave units (max. 4 units per master), ea. with an extinguishing volume of 4,4 m³. Vertical installation in lateral duct blinds is possible, this means no loss of HU in the rack.